Recoveries based on 83% thermal efficiency. ASHRAE 90.1 compliant for efficiency and standby loss.
"J" dimension is for the burner housing only. Gas train may exceed this dimension.
Standard gas train.
* The information presented is for Natural gas 0.6 S.G.— For operation with propane (LP gas), consult factory.
Dimensions are in inches unless otherwise specified.
Higher inputs available. Consult the factory.
For standard and optional equipment, see form PV 6046.
Model
Number
Recovery gph
Input
Btu/h
Min. Inlet Flow
Gas Pressure
"W.C.
#2 Oil
gph
Dimensions (inches)
Blower
Motor
Shipping
Weight
lbs
40°- 120°F 40°- 140°F A B C J HP
Volt/Ph/
Amps
750 N 900A-TPGO 750 600 600,000 4.5 4.3 46 6 1 31 1/2
115/1/10
3320
1000 N 900A-TPGO 1000 800 800,000 6.0 5.7 46 8 1 31 1/2
115/1/10
3360
1250 N 900A-TPGO 1250 1000 1,000,000 7.5 7.2 46 8 1 31 3/4
115/1/14
3450
1500 N 900A-TPGO 1500 1200 1,200,000 7.5 8.6 46 8 1-1/4 31 1
115/1/16
3530
2000 N 900A-TPGO 2000 1600 1,600,000 6.5 11.4 60 10 2 36 2
115/1/24
3740
2500 N 900A-TPGO 2500 2000 2,000,000 8.0 14.3 60 10 2 36 2
115/1/24
3860
TURBOPOWER
®
GAS/OIL PACKAGED WATER HEATER
NICKELSHIELD
®
NICKEL-PLATED STORAGE TANK
TANK SERIES 900 GALLONS
PV 5461 03/04
PVI INDUSTRIES, LLC
FORT WORTH, TEXAS 76111
(800) 784-8326
(817) 335-9531 www.pvi.com
Product is patented in the U.S., Canada, and Mexico.
STANDARD ELECTRICAL REQUIREMENTS
CONTROL VOLTAGE: 120V, 1Ø, 60 HZ., 2 AMPS.
MOTOR VOLTAGE:
208V, 230V, AND 460V MOTORS ARE AVAILABLE BUT WILL
REQUIRE A SEPARATE 120V/2 amps CONTROL CIRCUIT OR AN
OPTIONAL CONTROL CIRCUIT TRANSFORMER.
* REAR ACCESS MODULE
MODEL PREFIX M L STD or OPTIONAL
750-1500 23" 8" OPTIONAL
2000-2500 23" 8" STANDARD
* GAS PRESSURE REQUIREMENTS
SEE TABLE FOR MINIMUM PRESSURE BY MODEL NUMBER.
MAXIMUM STATIC INLET PRESSURE: 14" W.C.
FOR PRESSURES OTHER THAN LISTED, CONSULT FACTORY.
Pressure shown is for standard UL gas train. Additional controls
may increase pressure requirements.
VENTING REQUIREMENTS
-.02" TO -.06" W.C. (NEGATIVE PRESSURE)
ENTIRE VENT SYSTEM SHOULD NEVER BE SIZED BASED
UPON THE VENT CONNECTION DIAMETER EXCLUSIVELY.
FOR PROPER SIZING, CONSULT
THE NATIONAL FUEL GAS CODE UNDER “FAN-ASSISTED.”
PVI RESERVES THE RIGHT TO CHANGE THE DESIGN
AND SPECIFICATION WITHOUT NOTICE.